Safety Cabinet Solutions The Baker SterilGARD III advanced class II microbiological safety cabinet (possibly the world's finest range of class II safety cabinets) |
|
The Baker SterilGARD III advanced class II microbiological safety cabinet (class II
msc - possibly the world's finest class II safety cabinet), unlike the class I
microbiological safety cabinet (msc) provides protection for both the user
and the material within the
cabinet's working environment.
Protection for the user is provided by means of an advanced inflow air curtain whilst the sample material in the cabinet is protected from the dirty laboratory environment by a constant stream of hepa filtered air (airflow velocities inflow > 0.4 m/s and downflow between 0.25 and 0.5 m/sec). The Baker SterilGARD III advanced higher performance is dependant on this looped air management system of inflow and downflow air being maintained this is controlled by the ever reliable StediFLOW control system ensuring maximum filter life for the users. It's vital that one sites the cabinet in a suitably surveyed location (and if at all possible in accordance with current standard recommendations) within the laboratory and that wherever possible the cabinet is left uncluttered with items that will disrupt the downflow air flow (provisions can often be made when large items have to remain in the cabinet or when, say, a microscope is to be used). Note; both BS en12469 2000 and ACDP (advisory committee for dangerous pathogens) recommend that natural gas should not be used (as this will have an impact on the cabinets airflow, the downflow filter integrity and could possibly prove to be a fire hazard - several cabinets have been set alight this way), as such this should not be offered as a standard fixture on the class II msc. If, after a risk assessment it is deemed necessary to have natural gas then a special gas solenoid type tap together with a low profile, foot operated ignition type burner should be used. Seldom called 'a class II microbiological safety cabinet' and more commonly known amongst scientists, engineers, consultants and architects as hoods, flow hoods, safety cabinet, tissue culture cabinet and in the USA as a biohazard or biological safety cabinet to name a few. SCS Ltd advise on a consultancy basis (free of charge should products be purchased through SCS Ltd) on any concerns a perspective purchaser may have. The Baker SterilGARD III advanced class II msc provides optimum performance, lowest noise levels and numerous other advanced features. Just a few of the performance features included as standard on the Baker SterilGARD III class II microbiological safety cabinet include:
SCS ltd safety cabinet recommendations Safety Cabinet Solutions Ltd, doing it right first time!
The Dometic 'Powered by Baker' EN12469:2000
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||