There is no more a renowned company in the field of air containment and biological safety cabinets in the world than Baker. Designers of the world's first clean air cabinet. Performance, Reliability, Durability, Ergonomic design and Longevity are all a given on all Baker Company products - others follow Baker innovates and raises the bar....................

The Baker SterilGARD III advanced class II microbiological safety cabinets (class II msc - possibly the world's finest class II microbiological safety cabinet), unlike the class I microbiological safety cabinet (msc) provides protection for both the user, the environment and the material within the cabinet's clean air working environment.

Protection for the user is provided by means of an advanced inflow air curtain whilst the sample material in the cabinet is protected from the dirty laboratory environment by a constant stream of hepa filtered air (airflow velocities  inflow > 0.4 m/s and downflow between 0.25 and 0.5 m/sec).

The Baker SterilGARD III's advanced superior performance is dependant on this looped air management system of  inflow and downflow air being maintained this is controlled 24/7 by the ever reliable Baker StediFlow control system ensuring optimum performance and maximum filter life (the longest in the industry) for the users thus reducing life cycle costs.

It is essential that class II safety cabinet's are sited in the laboratory in a suitably surveyed location (and if at all possible in accordance with BS5726 recommendations and guidance 2005) within the laboratory and that wherever possible the cabinet is left uncluttered with items that will disrupt the downflow air flow (provisions can often be made when large items have to remain in the cabinet or when, say, a microscope is to be used). 

Note; both BS en12469 2000 and ACDP (advisory committee for dangerous pathogens) recommend that natural gas should not be used (as this will have an impact on the cabinets airflow, the downflow filter integrity and could possibly prove to be a fire hazard - several cabinets have been set alight this way), as such this should not be offered as a standard fixture on the class II msc. If, after a risk assessment it is deemed necessary to have natural gas then a special gas solenoid type tap together with a low profile, foot operated ignition type burner should be used.

Seldom called 'a class II microbiological safety cabinet' and more commonly known amongst scientists, engineers, consultants and architects as hoods, flow hoods, safety cabinet, tissue culture cabinet and in the USA as a biohazard or biological safety cabinet to name a few.

SCS Ltd advise on a consultancy basis (free of charge should products be purchased through SCS Ltd) on any concerns a perspective purchaser may have.

The Baker SterilGARD III advanced (probably the best msc available) class II msc provides optimum performance, lowest noise levels, longest filter life and numerous other state of the art features.

Just a few of the performance features included as standard on the Baker SterilGARD III advanced class II microbiological safety cabinet include:

  • StediFlow fan speed control provides assured life term performance

  • Baker’s Momentum air curtain provides superior containment

  • Standards: NSF49, EN12469:2000 and TUV compliant

  • Ergonomically designed, 10o sloped  front view screen

  • Glare free, 1450 lux flicker free internal lighting

  • Balanced airflows and exhaust uniformity

  • Low profile splash-proof electrical sockets

  • Extended filter life - average seven years 

  • Dependable soft touch control fascia

  • Ulpa exhaust & downflow filters

  • Quiet <54dBA noise level

  •  Established reliability

  •  It’s a Baker msc!

          